CADDX NX-6 Manuale di Installazione Pagina 25

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 104
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 24
GE Security
g
[*]-[CHIME] ACTIVATING WALKTEST
1. Enter [*]-[CHIME]
The LCD screen will prompt you for a “master
code”.
2. Enter [mastercode] The LCD screen will display the “walktest mode”
3. Activate all sensors to test
Each activation of a sensor is confirmed with a
“ding dong” sound. The zone texts of the sensors
who have reacted, are displayed one by one on the
screen.
4. Enter [mastercode] The walktest mode is left.
Remark:
1. All activations and restore conditions occurred during the walk test, can
be verified by consulting the memory file (see function [*]-[9]-[0])
2.
A walk test mode is not possible if any partition is armed or if the
communicator is active.
NX-6-EUR Installation manual Page 25 23/12/04
Vedere la pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 103 104

Commenti su questo manuale

Nessun commento